1 3
2
31
7/8-14 UNF - 2A
17,5
15,9
46,6
48
114,5
max.
23
26,8
123,3
max.
Hex. 5
Hex. 17
Hex. 27
CFCT-060-MHRR
SAE-10-3N
50 - 57 Nm
1
2
3
60
5,8-9
Screw nut locknut
AT000021
CF000006
CFCT-060-MHRR-09-S10-N350
CFCT-060-MHRR-12-S10-N350
CFCT-060-MHRR-16-S10-N350
CFCT-060-MHRR-32-S10-N350
CF000054
CF000062
CF000057
60
60
60
60
2,5-3,5
8,5-12
11,5-16,5
26,5-38,5
3 WAYS COMBINATION
ADJUSTABLE SETTING
With 3 way
2 way, port
2 not connected
Screw nut locknut
Screw nut locknut
Screw nut locknut
Screw nut locknut
CFCT-060-MHRR-30-S10-N350
Screw nut locknut
60
CF000152
20-29,5
15,5-22,5
CFCT-060-MHRR-23-S10-N350
Screw nut locknut
60
CF000151
CF000150
CFCT-060-MHRR-06-S10-N350
60
4,2-6,2
Screw nut locknut
3-4,5
60
Screw nut locknut
CF000149
CFCT-060-MHRR-04-S10-N350
0,28 kg
SPECIFICATIONS
ORDERING CODES
Max. operating pressure:
Rated flow:
Weight:
FLOW REGULATOR
Cavity:
Atlantic
Fluid Tech
Quick
code
Description
Max. Inlet
Flow
(l/min)
Adjust.
range
(bar)
Reg. Flow
range
(l/min)
CF000063
CFCT-060-MHRR-03-S10-N350
350 bar
60 l/min
Installation torque:
SEALING CAP
Ordering code:
NOTES
If port 2 is blocked the valve operates
as a two way flow regulator.
Port 3 pressurizedPort 2 pressurized
30
25
0 40 120 160 200
0
5
10
20
15
REGULATED FLOW
(l/min)
80
PRESSURE (bar)
Seal kit: RA700092